Step 4: Battery ready to use
Step 7: Fully charged battery
Step 8: Maintenance charging
COLD/AGM: Charging in cold conditions, AGM and Stop-Start batteries
RECOND: Recondition of deeply discharged batteries
SMALL: Program for charging small batteries
NORMAL: Program for charging normal batteries
Volt | 12V |
Rated Voltage AC | 220–240VAC, 50–60Hz |
Charging voltage | SMALL, NORMAL: 14.4V, COLD/AGM: 14.7V, RECOND: 15.8V |
Min battery voltage | 2.0V |
Charging current | 5A max |
Current, mains | 0.6A rms (at full charging current) |
Back current drain | <1Ah/month |
Ripple | <4% |
Ambient temperature | -20°C to +50°C, output power is reduced automatically at high temperatures |
Charger type | 8 step, fully automatic charging cycle |
Battery types | All types of 12V lead-acid batteries (WET, MF, Ca/Ca, AGM and GEL) |
Battery capacity | 1.2–110Ah up to 160Ah for maintenance |
Dimensions | 168 x 65 x 38mm (L x W x H) |
Insulation class | IP65 |
Weight | 0.6kg |
Temperaturkompensation | Built in charge voltage compensation according to ambient temperature |